APC Smart-UPS 2200 LCD - UPS (rackversio) - AC 220/230/240 V - 1,98 kW - 2200 VA - RS-232, USB - output-stikforbindelser: 9 - 2U - for P/N: AR4018SPX432, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, NBWL0356A
Osta huoletta joululahjoja 🎁 90 päivän palautusoikeus* avaamattomille tuotteille
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Tuotetta ei ole varastossa. Lisätietoja

Kuljetuksen hinta 150,60 Kuormalavatoimitus katutasolle (arkisin 8:00-16:00)
– Takaraja klo 15.00 toimituksen lähtöön samana päivänä

Toimituskulut on laskettu vastaanottajan postinumeron perusteella: - Vaihda postinumero
Syötä postinumero toimitusta varten: Tallenna

Loppuunmyyty

Tuotetta ei ole varastossa.

EUR 2.333,91
ilman ALV 1.859,69
Kokonaishinta sis. toimitus 2.484,51
Ilmoita minulle, kun tuotetta on jälleen tarjolla varastossa
Cold-start capable\nProvides temporary battery power when the utility power is out.\n\nEnergy meter\nProvides actual kilowatt hours of usage for energy conscious users.\n\nGreen mode\nPatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\n\nHigh online efficiency\nReduces utlility costs, generates less heat.\n\nIntuitive LCD interface\nProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.\n\nPredictive replace battery date\nDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.\n\nSingle switched outlet group\nSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.\n\nSmartSlot\nCustomize UPS capabilities with management cards.\n\nTemperature-compensated battery charging\nProlongs battery life by regulating the charge voltage according to battery temperature.\n\nAvailability\n\nDisconnected battery notification\nWarns when a battery is not available to provide backup power.\n\nAutomatic restart of loads after UPS shutdown\nAutomatically starts up the connected equipment upon the return of utility power.\n\nAutomatic self-test\nPeriodic battery self-test ensures early detection of a battery that needs to be replaced.\n\nIntelligent battery management\nMaximizes battery performance, life, and reliability through intelligent, precision charging.\n\nTemperature-compensated battery charging\nProlongs battery life by regulating the charge voltage according to battery temperature.\n\nBoost and Trim Automatic Voltage Regulation (AVR)\nGives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).\n\nPower conditioning\nProtects connected loads from surges, spikes, lightning, and other power disturbances.\n\nManageability\n\nNetwork manageable\nProvides remote power management of the UPS over the network.\n\nSerial connectivity\nProvides management of the UPS via a serial port.\n\nAudible alarms\nActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.\n\nDisconnected battery notification\nWarns when a battery is not available to provide backup power.\n\nLED status indicators\nQuickly understand unit and power status with visual indicators.\n\nUSB connectivity\nProvides management of the UPS via a USB port (not available on all models).\n\nSafety\n\nSafety-agency approved\nEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\n\nMarketing Features\n\nLow operating and maintenance costs with high efficiency, proven reliability and intelligent battery management\nPatented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging.\nDynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.\n\nSave time with easy and convenient remote accessibility\nNetwork manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.\n\nSmarter productivity with ability to tailor to your specific application needs\nIntuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.\n\nPeace of mind that comes with full equipment compatibility and reliability of a leader\nProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.\n\nAvoids costly power problems by keeping your IT equipment and data safe and available\nNetwork grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systems\n\nServiceability\n\nResettable circuit breakers\nEnables a quick recovery from overload events.\n\nHot-swappable batteries\nEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\n\nPredictive failure notification\nProvides early-warning fault analysis ensuring proactive component replacement.\n\nUser-replaceable batteries\nIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\n\nBattery failure notification\nProvides early-warning fault analysis on batteries enabling timely preventive maintenance\n\nAdaptability\n\nAdjustable voltage-transfer points\nMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.\n\nAdjustable voltage sensitivity\nProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.